Name: Israel Beltran
College: He graduated from Mayfield College (HVAC) and has certifications in HVAC, EPA, forklift operator and business management.
Favorite Aspect of My Job: Izzy’s favorite aspect of his job is being able to learn new things about HVAC and the ability to do ten things at once.
Hobbies: When he is not working and supervising at Hydes, Izzy enjoys spending time with family and hobbies that include, sports, cars and music.
Interesting Fact About Me: Israel a.k.a. “Izzy” has been a part of the Hydes work family for over two years although he has worked in the HVAC industry for seven years.
Customers say: The reviews exhibit a positive sentiment towards Hydes Air Conditioning. Customers consistently praise the company for its professionalism, punctuality, expertise, and exceptional service. Many reviewers mention the welcoming and family-like atmosphere, with employees who are described as cheerful, helpful, and knowledgeable. Customers also appreciate the company's attention to detail, efficiency, and the overall experience. Additionally, Hydes is recognized for its commitment to customer satisfaction, with prompt responses to inquiries, accurate quotes, and follow-ups to ensure complete customer satisfaction. The technicians are often described as courteous, friendly, and willing to go the extra mile to address any concerns or questions. Overall, the reviews convey a sense of trust, reliability, and satisfaction with Hydes Air Conditioning's services.
Greg fixed our problem and did an excellent recap of all that he did. Also explained how to go forward. Thank you.
We love Hyde for their excellent staff and impeccable service!
Got measurements of registers
issue resolved
replaced 1050 loosing internet signal --- Tstat location wall is bowed --secured back plate with anchors --tstat snap into place without an issue
tech left furnace "jumped"--removed jumper system turned off
Follow up from 12–07-2024 Reference bedroom furnace, thermostat located in master bedroom attic access in hallway—-furnace serial number 3288 located in attic—-1) check tighten low-voltage control wires at furnace terminal block 2) check tighten control wires going to gas valve—3) clean burner assembly, and ignition assembly—-test unit three times in heat—-heating system is operating as designed
Heating System Repair: A commercial facility reported insufficient heat in certain areas. Upon inspection, I discovered a malfunctioning circulator pump in their boiler system. I replaced the pump, ensuring hot water was evenly distributed for consistent warmth.
filters had been changed----equipment needs cleaning general usage / maintenance--very little signs of remodel at units
client was called---"red X" top right corner equals no internet--client good
System had fault codes of 184 family —-(lockout codes)found unit low on refrigerant. System is Heating at present time hundred degree supply air—-Will get with Client on when and how will conduct a league search client would like it done as soon as possible.
Installed water heater
Installed plumbing for humidifier and reset thermostats
deliver part
Installed a 5 Ton Silver 15 Horizontal Split Heat Pump System. Will use crane to remove old unit and install new unit. $2000 federal tax credit available after installation. $1500 instant rebate available from state. Repair credit from recent thermostat. Will disconnect existing zoning and use one thermostat. 0% financing is available for 18 months. Job complete.
Replace gas valve and thermocouple—-unit was cycled several times in heat—-system is running as designed—-confirmed no gas leaks from gas valve replacement—— monitored system for CO none detected—-system is operating per manufacturer specification
Pressurized flat system to 550 psi in order to locate leak, located leak and repaired, pressure system to 550 psi for 15 minutes set system on vacuum to 500 µm Charge system back to Manufacturer specifications, 7 lbs. 3 oz. refrigerant And tested system. System is operating properly system was recently installed labor Under warranty
No heat = Repair as required —- test heat cycle several times —-heating is working as required—-Temperature rise within specification—-see Notes
client was called---client does have unit in heat mode (red numbers)---unit is possibly putting out cold air---might be defrost mode --or other client to call back if home continues to drop temp
both furnaces (ultra low nox) not working---SN 30LG live unit adjust manifold gas pressure (run 2.26)--temp rise 36---S/N B3LG bed unit adjust manifold gas pressure (run 2.3)--temp rise 43---furnace noise OK 2X
Circuit board was replaced could not get personality module to communicate with Wi-Fi/circuit board will return Monday 9 to 11 time # hydes
Found Molex plug at circuitboard going to the inducer motor faulty ordered new circuit board and installed tomorrow
client was called --nest tstat--client figured it out
client was called --connected with client----disconnecting your wifi from your tsat should not affect function of thermostat
client was called---no answer and no message machine
Upon arrival heating not working giving 3 flashing lights indicating pressure switch stuck open advised we will speak to homeowner to send technician out for diagnosis
client called ---going to inspect garage access point into attic